GY00 Simple Beauty capsule pods in a commercial double-deck room layout
Single Capsule Pods · GY00 Series

GY00 Simple Beauty Capsule Pods

Six single-guest models combine three equipment tiers with A and B opening formats. Compare privacy, horizontal and vertical planning, dimensions, utilities and project inputs before configuration.

Series
GY00 Simple Beauty
Models
6 variants
Layouts
Horizontal / vertical*
Electrical
110–240 V AC / 12 V cabin
Model matrix

Three equipment tiers, two opening formats

A models support horizontal or vertical layouts. B models use a wider two-thirds-open entrance and are documented for horizontal planning only.

Equipment tierA · Half-openB · Two-thirds-open
01Light LuxurySilent-curtain entrance
GY001-AHalf-open

GY001 uses the shared Simple Beauty shell with a silent fabric curtain and internal latch for a streamlined privacy package.

  • Horizontal: 2200 × 1120 × 1513 mm approx.
  • Vertical: 2180 × 1050 × 1513 mm approx.
GY001-BTwo-thirds-open

GY001 uses the shared Simple Beauty shell with a silent fabric curtain and internal latch for a streamlined privacy package.

  • Horizontal: 2200 × 1120 × 1513 mm approx.
02FlagshipSmart-door entrance
GY002-AHalf-open

GY002 adds a safety sliding door, smart card lock, internal latch, escape label and luminous operating label.

  • Horizontal: 2200 × 1120 × 1513 mm approx.
  • Vertical: 2180 × 1050 × 1513 mm approx.
GY002-BTwo-thirds-open

GY002 adds a safety sliding door, smart card lock, internal latch, escape label and luminous operating label.

  • Horizontal: 2200 × 1120 × 1513 mm approx.
03LuxuryEnhanced ceiling and alarm
GY003-AHalf-open

GY003 combines the smart-door package with a larger multicolour Simple Beauty ceiling and an independent in-pod smoke alarm.

  • Horizontal: 2200 × 1120 × 1513 mm approx.
  • Vertical: 2180 × 1050 × 1513 mm approx.
GY003-BTwo-thirds-open

GY003 combines the smart-door package with a larger multicolour Simple Beauty ceiling and an independent in-pod smoke alarm.

  • Horizontal: 2200 × 1120 × 1513 mm approx.

* Approximate single-deck dimensions are shown. Double-deck, ladder, circulation and service clearances must follow the approved project drawing.

Series advantages

Four reasons to specify GY00

01

Six clear configurations

Three equipment tiers pair with A and B opening formats, giving buyers a structured model choice without fragmenting the product family.

02

Flexible A-type planning

GY001-A, GY002-A and GY003-A support horizontal or vertical layouts, helping projects respond to room frontage and circulation constraints.

03

Tiered privacy packages

GY001 uses a silent curtain, while GY002 and GY003 add smart-card sliding-door access; GY003 further adds an enhanced ceiling and smoke alarm.

04

Integrated cabin systems

Low-voltage controls, charging, lighting, negative-ion purification and adjustable circulation form a coordinated in-pod environment.

Openings and orientation

Choose the entrance, then plan the room

A

Half-open A format

Available across GY001-A, GY002-A and GY003-A. GY001-A uses a curtain; GY002-A and GY003-A use a smart-card sliding door.

Horizontal + vertical
B

Two-thirds-open B format

Available across GY001-B, GY002-B and GY003-B. The wider entrance format is listed only for horizontal room planning.

Horizontal only
H

Horizontal layout

Available for all six models. A double-deck set uses six circulation modules and includes a ladder and handrail; allow for aisle and ladder projection.

V

Vertical layout

Available only for A models. A vertical double-deck set uses four circulation modules; confirm entry, ceiling, service and circulation clearances.

Best-fit projects

Where GY00 works best

GY00 suits repeatable single-guest accommodation that benefits from tiered privacy and a choice between horizontal and space-conscious vertical planning.

Final occupancy, accessibility, fire safety, cleaning, operations and destination approvals remain project-specific.

  1. 01capsule hotels and hostels with mixed room geometries
  2. 02airport, station and transit rest facilities
  3. 03staff, workforce and student accommodation
  4. 04commercial rest rooms needing tiered privacy options
Site coordination

Electrical, ventilation and materials

Confirm all utility, material and compliance requirements against the destination market and final configuration.

Electrical

110-240 V AC input feeds a 12 v low-voltage cabin system. Confirm frequency, plugs, sockets, connection method, circuit protection and available load.

Ventilation

Adjustable circulation, approximately 30 m³/h. The listed circulation system is approximately 30 m³/h with five speed levels; it does not replace building HVAC or fresh-air design.

Materials and flame-retardant options

Simple Beauty ABS shell with a metal structural frame. General, V2 or V0 ABS may be selected subject to final configuration and matching evidence. A material report is not whole-pod fire certification.

Installed GEELYE capsule pods illustrating project-specific installation support
Model-specific installation support

GY00 assembly guidance follows the confirmed configuration

Assembly steps, components and connection details vary by series and order. GEELYE supplies the applicable video or drawings and provides remote guidance after the model, configuration and project scope are confirmed.

Request installation guidance
Before configuration

What the buyer needs to provide

Room, access, utility, quantity and model information allows GEELYE to confirm feasibility, drawings, options and configuration-specific packing.

  • project country, city, building type and intended operation
  • dimensioned room plan, ceiling height, fixed obstructions and site photographs
  • required quantity, single-deck or double-deck count and preferred orientation
  • selected model, A/B opening format and entrance direction
  • local voltage, frequency, plug/socket standard and connection method
  • room HVAC, fresh-air, return-air and drainage conditions
  • delivery route dimensions, unloading access and installation restrictions
  • requested colour, ABS grade, options, branding and local compliance requirements

Commercial terms

Confirmed Ordering & Delivery Terms

Use these published terms as the starting point for a GEELYE quotation. The selected model, configuration, named port and final order scope are confirmed in the quotation.

Review Certification Scope Published material and component documents do not certify the complete pod.
MOQ
1 set
Trade term
FOB
Sample lead time
15 days
Bulk lead time
15–30 days
Sample
Sample fee required
Packaging
Paper-based packaging
Installation
Customer installation · video provided

Include with your inquiryProduct type or series, estimated quantity, destination or named port, room dimensions or plan, required configuration and target schedule.

Request a Product Quotation
Commercial handover

Packaging, shipping, installation and warranty

Manufacturer: Byeast International Group CO.,Ltd

01

Packaging

Packaging method, carton count, packed dimensions and gross/net weight are provided after the final configuration is confirmed.

02

Shipping

FOB terms; the named port is confirmed in the quotation or sales contract.

03

Installation

Customer installation; GEELYE provides an installation video and written instructions. Site labour, tools and unloading remain the customer's responsibility unless otherwise contracted.

04

Warranty

Two-year product warranty. Paid lifetime maintenance support is available afterward, subject to parts availability and agreed service terms.

Plan a GY00 project

Send the room plan, quantity and opening choice.

GEELYE can review model selection, orientation, deck count, utilities, delivery access and ABS grade against the project requirements.

Request a Quote
Product inquiry

Get a Quote

Share your contact details and purchasing requirements. The selected product and page context are included automatically.

By submitting, you agree that GEELYE may use these details to respond to your inquiry. Privacy